Future-Ready ST100 Flow Meter Is SIL Compliant

Aug. 1, 2013
Process and plant engineers in search of a next-generation air/gas flow meter that is suitable for critical operations and hazardous environments will find that the future-ready ST100 Series Thermal Mass Air/Gas Flow Meter from Fluid Components International (FCI) is now rated for Safety Integrity Level (SIL) 1 compliant service.

Process and plant engineers in search of a next-generation air/gas flow meter that is suitable for critical operations and hazardous environments will find that the future-ready ST100 Series Thermal Mass Air/Gas Flow Meter from Fluid Components International (FCI) is now rated for Safety Integrity Level (SIL) 1 compliant service.
FCI’s SIL compliance rating for the ST100 Flow Meter has been documented in a failure analysis report with FMEDA techniques by Exida, an accredited global functional safety certification company.  The ST100 Flow Meter has been classified as a Type B subsystem in accordance to IEC 61508-1 with a hardware failure tolerance of 0. The Probability of Failure on Demand (PFD) meets SIL-1 capability standards.

SIL ratings provide a key assurance of confidence that safety rated equipment has been tested and shown to prevent dangerous failures and to control them in the event they occur.  FCI’s new SIL-1 safety compliance assures its customers that the third-party testing organization (Exida) has tested the ST100 Flow Meter and when the product is in use, the processrisk is reduced to the designated level.  FCI’s customers can rely on the company to improve safety and reliability continually.

The ST100 Series Flow Meter sets a new industry benchmark in process and plant air/gas flow measurement, offering the most feature-rich and function-rich electronics available.  The ST100’s performance delivers unsurpassed adaptability and value to meet plant gas flow measurement applications for today and tomorrow.

Whether the need is for 4-20 mA analog, frequency/pulse, alarm relays or digital bus communications such asHART, Fieldbus, Profibus or Modbus, the ST100 is the solution. Should a plant’s needs change over time or an upgrade be desirable, the ST100 Flow Meter adapts as necessary with a plug-in card replacement that can be changed out by plant technicians in the field.

The ST100 Flow Meter’s unique graphical, multivariable, backlit LCD display/readout brings new meaning to the term “process information”. It provides the industry’s most comprehensive information with continuous display of all process measurements and alarm status, and the ability to interrogate for service diagnostics.

The user-friendly ST100 stores up to five unique calibration groups to accommodate broad flow ranges, differing mixtures of the same gas and multiple gases, and obtains up to 1000:1 turndown.
Also standard is an on-board data logger with an easily accessible, removable 2-GB micro-SD memory card capable of storing 21 million readings.

The ST100 is the first thermal flow meter to offer three different types of flow sensors to best match user applications.  The fast-response FPC-style is a fast response features an integral flow conditioner and protective shroud optimized for compressed air and clean gas applications.   The fast-response, general purpose FP-style features a protective shroud and is the sensor used with FCI’s VeriCal™ in-situ calibration option.  For wet or dirty gases, or erratic flows, the unshrouded S-style facilitates easy cleaning and provides a smoothed response.

The comprehensive ST100 Series is comprised of two core model families: ST and STP.   ST meters measure both mass flow and temperature, and the exclusive STP family adds a third parameter, pressure, making the ST100 the world’s first triple-variable thermal flow meter.  Both families include single-point and dual-element models as configurations outfitted with FCI’s exclusive in-situ calibration option, VeriCal.

The ST100 can be calibrated to measure virtually any process gas, including wet gas, mixed gases and dirty gases.  The basic insertion style air/gas meter features a thermal flow sensing element that measures flow from 0.25 to 1000 SFPS (0.07 NMPS to 305 NMPS) with accuracy of  ±0.75 percent of reading, ±0.5 percent of full scale.   

Designed for rugged industrial processes and plants, ST100 Flow Meters include service up to 850ºF (454ºC) and are available with both integral and remote (up to 1000 feet [300 meters]) electronics versions. The ST100 is agency approved for hazardous environments, including the entire instrument, the transmitter and the rugged, NEMA 4X/IP67 rated enclosure.  Instrument approvals in addition to SIL-1 include ATEX, IECEx, FM and FMc.

>>For more information on this product, click here
 

Companies in this Article

Sponsored Recommendations

Why Go Beyond Traditional HMI/SCADA

Traditional HMI/SCADAs are being reinvented with today's growing dependence on mobile technology. Discover how AVEVA is implementing this software into your everyday devices to...

4 Reasons to move to a subscription model for your HMI/SCADA

Software-as-a-service (SaaS) gives you the technical and financial ability to respond to the changing market and provides efficient control across your entire enterprise—not just...

Is your HMI stuck in the stone age?

What happens when you adopt modern HMI solutions? Learn more about the future of operations control with these six modern HMI must-haves to help you turbocharge operator efficiency...

AVEVA™ System Platform: Smarter, Faster Operations for Enhanced Industrial Performance

AVEVA System Platform (formerly Wonderware) delivers a responsive, modern operations visualization framework designed to enhance performance across all devices with context-aware...