Reduced Maintenance and Enhanced Custody Transfer on Pipeline

Jan. 4, 2013
Adria-Wien Pipeline GmbH (AWP) has upgraded turbine flowmeters for custody-transfer measurement on the Adria-Wien pipeline in Austria.

The company replaced existing turbine flowmeters with Micro Motion Elite High Capacity Coriolis flowmeters from Emerson Process Management (www.emersonprocess.com). AWP is focusing on using the latest technologies in its plants and automation. "Concerns over reliability and maintenance of the turbine meters prompted our upgrade to the latest measurement technology," said Ing. Walter Fellner, Adria-Wien Pipeline GmbH. "We chose Emerson’s Micro Motion Elite high capacity flowmeters because they are maintenance free and exceeded our accuracy needs for custody transfer."

The Adria–Wien pipeline carries crude oil from the Transalpine pipeline at the Italian-Austrian border to the Schwechat refinery near Vienna, Austria.

Emerson supplied two Micro Motion Elite High Capacity flowmeters with MVD (multivariable digital) transmitters. The flowmeters were added to the refinery infeed lines in a parallel arrangement that allowed them to be installed individually without interrupting the flow of crude oil.

Emerson’s Rosemount 3144P temperature transmitters were also installed to provide accurate line flow temperature measurements, as required by the Measuring Instruments Directive (MID) Regulations. The temperature data is used to compensate for the effects of temperature on volume flow in custody transfer applications. Data from the Coriolis flowmeters and temperature transmitters is communicated to the existing host system using an RS485 Modbus connection.

To help AWP ensure the accuracy of its custody transfer measurements, the Elite High Capacity Coriolis flowmeters also feature Emerson’s Smart Meter Verification -- an easy-to-use, automatic diagnostic tool that quickly verifies the complete meter performance (sensor, drive and signal processing) without interrupting the flow measurement or process flow. This allows meter performance to be tracked without removing it from pipeline.

The Elite High Capacity range includes ten sensor models covering DN150-DN400 (6-16 inch) line sizes. They have flow rates up to 3,266 tons/hour and density accuracies of ±0.0005 grams per cubic centimeter.

Companies in this Article

Sponsored Recommendations

Why Go Beyond Traditional HMI/SCADA

Traditional HMI/SCADAs are being reinvented with today's growing dependence on mobile technology. Discover how AVEVA is implementing this software into your everyday devices to...

4 Reasons to move to a subscription model for your HMI/SCADA

Software-as-a-service (SaaS) gives you the technical and financial ability to respond to the changing market and provides efficient control across your entire enterprise—not just...

Is your HMI stuck in the stone age?

What happens when you adopt modern HMI solutions? Learn more about the future of operations control with these six modern HMI must-haves to help you turbocharge operator efficiency...